Stahlock

Guides · En español

Panic Bar Height: 864-1219 mm US, 900-1100 mm Europe

Mount a panic bar 864 to 1219 mm (34 to 48 in) above the finished floor in the US under the IBC and NFPA 101, and 900 to 1100 mm in Europe per EN 1125 installation instructions. Order bar length by door width: at least half the leaf in the US, 60% in Europe.

The set to order

PartWhat to checkModels
Bar 650, 800 or 1000 mmThree listed lengths, customizable, with a built-in alarm. State the length and any option on the order line.314
Touch bar 800 or 1000 mmTwo listed lengths. Painted iron, surface mounted.315
Bar 900 mmAll three are listed with an adjustable length. Send the door width.300, 303, 310
Bar 1000 mm, single doorThe 306-S bar can be cut to door width. 308-S is 1025 mm overall. 301-B and 307 are adjustable.301-B, 306-S, 307, 308-S
Bar 1040 mmAll three are published at 1040 mm. 302 and 304 are adjustable in length and bolt height.302, 304, 305
Bar 1050 mmLength is customized to door width.303-H, 303-J
Bar 1000 to 1200 mm, double door308-D 1000 mm, 309-D 1100 mm, 306-D 1200 mm. Bar length here is per device, so check it against the leaf that carries it.308-D, 309-D, 306-D
Length made to your doorNo fixed length listed. The length is set by your request.320, 330

Mounting height by region

Measure from the finished floor to the center line of the bar, with the door closed. The finished floor is the top of the tile, carpet or screed, not the slab. A bar set before the floor goes down ends up low, so take the level from the floor finish drawing.

A bar at 1000 mm (about 39 in) sits inside both the US and the European range. That one height suits a door schedule that serves both markets, unless a local rule says otherwise.

WhereSourceHeight above finished floor
US, new workIBC and NFPA 101864 to 1219 mm (34 to 48 in)
US, existing installationsNFPA 101762 to 1219 mm (30 to 48 in)
EuropeEN 1125 installation instructions900 to 1100 mm
California, operable hardwareState rule864 to 1118 mm (34 to 44 in)
Massachusetts, operable hardwareState rule914 to 1219 mm (36 to 48 in)

What moves the height on a real door

  • A steel door may have its reinforcement welded in at a fixed height. Read the door drawing first.
  • A vision panel or a mid rail can block the fixing line. Move the bar, not the screws.
  • A device with a mortise lock case takes its height from the lock cut-out.
  • The outside trim sits on the pull side at the same height as the bar.
  • EN 1125 instructions advise a lower bar where the users are mainly young children.
  • Rules vary by state and country. Confirm the height with the local authority before you drill.

Bar length against door width

US practice asks for a bar no shorter than half the door width. European practice asks for at least 60% of the leaf width, and EN 1125 instructions advise the longest effective length the door allows. Use the wider figure when one schedule serves both.

Most Stahlock bars are published with an adjustable length, so a stock length is a starting point. The final cut length is confirmed against your drawing.

Leaf widthMinimum bar, US (50%)Minimum bar, Europe (60%)
800 mm400 mm480 mm
900 mm450 mm540 mm
1000 mm500 mm600 mm
1200 mm600 mm720 mm
1300 mm650 mm780 mm

Other listed push bar dimensions

Projection is the distance the device stands off the door face. It takes space from the clear opening, so ask the architect to check clear width with the door open. Anything not shown here is confirmed against your drawing.

ModelBar lengthProjectionListed door size
306-S1000 mm85 mmUp to 1300 mm wide
306-D1200 mm85 mmUp to 1300 × 2500 mm (W × H)
308-S1000 mm, 1025 mm overall93 mmNot published
308-D1000 mm, 1025 mm overall93 mm2400 mm high with top and bottom rods
309-D1100 mm85 mmNot published
313Not publishedNot publishedUp to 1500 mm wide and 2520 mm high

What to send with the order

  • Leaf width and height in mm.
  • Door thickness in mm.
  • Door material: steel, aluminum or wood.
  • Single door or pair.
  • Bar height above the finished floor.
  • Hinge side, seen from the pull side.
  • Whether people enter from outside, which decides the trim.

Questions buyers ask

What is the standard height for panic hardware?

In the US it is 864 to 1219 mm (34 to 48 in) above the floor under the IBC and NFPA 101. In Europe, EN 1125 installation instructions give 900 to 1100 mm. Some US states set a tighter range, so confirm with the local authority.

How long should a push bar be on a 900 mm door?

At least 450 mm in the US and 540 mm in Europe. Models 314 and 315 are published at 800 mm. Models 300, 303 and 310 are published at 900 mm with an adjustable length, so send the door width and the cut length is confirmed against your drawing.

Which side of the door does the bar go on?

The bar goes on the push side of an outward-opening door, which is the side people reach as they leave. The outside trim goes on the pull side.

Can one height serve both US and European projects?

Yes, in most cases. A bar at 1000 mm (about 39 in) falls inside both ranges. Check it against the door reinforcement and any local rule before you fix it across a project.

Should the bar be lower in a school?

EN 1125 instructions advise a lower bar where the users are mainly young children. The US range still starts at 864 mm (34 in). Ask the local authority for the height it accepts for that building.

Sources

Codes change and vary by place. Confirm with the authority for your project.

Read next